Description

Accuracy and diagnostic functions for maximum industrial productivityThe new Fluke 87V has improved measurement functions, trouble-shooting features, resolution and accuracy to solve more problems on motor drives, in plant automation, power distribution and electro-mechanical equipment.

The New Fluke 80 Series consists on the following models:
  • Fluke 83 V Industrial DMM
  • Fluke 87 V True RMS Industrial DMM
  • Fluke 87 V/E2 Industrial Electricians Combo Kit
  • Data logging DMM available
The 80 Series V operates very similar to the classic 80 series, but with more problem solving power, safety, convenience and impact protection.

The new 80 series V are independently tested to comply with the 2nd edition of ANSI/ISA S82.01 and EN61010-1 CAT IV 600V/CAT III 1000V. They can withstand impulses in excess of 8,000 V and reduce risks related to surges and spikes.

FEATURES
  • Unique function for accurate voltage and frequency measurements on adjustable speed motor drives and other electrically noisy equipment (87V)
  • Built-in thermometer conveniently allows you to take temperature readings without having to carry a separate instrument (87V)
  • Optional magnetic hanger for easy set-up and viewing while freeing your hands for other tasks
  • Large digit display with bright, two-level backlight makes the 80- Series V significantly easier to read than older models

Specifications
Voltage DC
Maximum Voltage: 1000V
Accuracy: Fluke 83 V: ±(0.1%+1)
Fluke 87 V: ±(0.05%+1)
Maximum Resolution: Fluke 83 V: 100 µV
Fluke 87 V: 10 µV
Voltage AC
Maximum Voltage: 1000V
Accuracy: Fluke 83 V: ±(0.5%+2)
Fluke 87 V: ±(0.7%+2) True RMS
AC Bandwidth Fluke 83 V: 5kHz
Fluke 87 V: 20kHz*
*with low pass filter; 3db @ 1kHz
Maximum Resolution: 0.1 mV
Current DC
Maximum Amps: 10A (20 A for 30 seconds maximum)
Amps Accuracy: Fluke 83 V: ±(0.4%+2)
Fluke 87 V: ±(0.2%+2)
Maximum Resolution: Fluke 83 V: 0.01 mA
Fluke 87 V: 0.01 µA
Current AC
Maximum Amps: 10A (20 A for 30 seconds maximum)
Amps Accuracy: Fluke 83 V: ±(1.2%+2)
Fluke 87 V: ±(1.0%+2) True RMS
Maximum Resolution: 0.1 µA
Resistance
Maximum Resistance: 50 MΩ
Accuracy: Fluke 83 V: ±(0.4%+1)
Fluke 87 V: ±(0.2%+1)
Maximum Resolution: 0.1Ω
Capacitance
Maximum Capacitance 9,999 µF
Accuracy ±(1%+2)
Maximum Resolution 0.01 nF
Frequency
Maximum Frequency 200 kHz
Accuracy ±(0.005%+1)
Maximum Resolution 0.01 Hz
Duty Cycle
Maximum Duty Cycle 99.9%
Accuracy ±(0.2% per khz +0.1%)
Maximum Resolution 0.1%
Temperature Measurement
Fluke 87 V, 87 V/E: -200.0°C - 1090°C

-328.0°F - 1994.0°F

excluding probe
80 BK Temperature Probe

-40.0°C - 260°C

-40.0°F - 500°F, 2.2°C or 2% whichever is greater
Conductance
Maximum Conductance 60.00 nS
Accuracy ±(1.0%+10)
Maximum Resolution 0.01 nS
Diode
Range: 3 V
Resolution: 1 mV
Accuracy: ± (2 % + 1)
Duty Cycle Range
Accuracy: Within ± (0.2% per kHz + 0.1 %)


Distributed By : www.ralali.com ,Distributor FLUKE Indonesia

Multimeter Fluke 27 II/28 II Industrial

Multimeter Fluke 27 II/28 II Industrial

Lihat lainnya di www.ralali.com


Multimeter Fluke 27 II/28 II Industrial

Description

The NEW standard for ruggedThe NEW digital multimeters Fluke 27 II and 28 II digital multimeters define a new standard for operating in harsh conditions with the features and accuracy to troubleshoot most electrical problems. Both meters have IP 67 (waterproof and dustproof) rating, MSHA approvals (pending), extended operating temperature range of -15 °C to +55 °C (5 °F to 131 °F, -40 °C for up to 20 minutes) and 95 % humidity, and have been designed and tested to withstand a 3 m (10 ft) drop. The new Fluke 20 Series Multimeters are built to work in the toughest environments.

FEATURES
  • Measure up to 1000 V ac and dc
  • Measure up to 10 A (20 A for 30 seconds)
  • 10,000 μF capacitance range
  • Frequency to 200 kHz
  • Extended ac voltage bandwidth– 15 Hz to 20 kHz (28 II), 40 Hz to 30 kHz (27 II)
  • Built in thermometer conveniently allows you to take temperature readings without having to carry a separate instrument (28 II)
  • Resistance, continuity and diode test
  • Min/Max and average recording to capture variations automatically
  • Peak min-max (28 II)
  • Unique function for accurate voltage and frequency measurements on adjustable speed motor drives and other electrically noisy equipment (28 II)

SPESIFICATIONS
Accuracy specifications
DC voltage
Range 0.1 mV to 1000 V
Accuracy 27-II:0.1 % +1
28-II:0.05 % + 1
AC voltage
Range 0.1 mV to 1000 V
Accuracy 27-II: 0.5 % +3
28-II: 0.7 % +4
DC current
Range 0.1 μA to 10 A
Accuracy 27-II: 0.2 % + 4
28-II: 0.2 % + 4
AC current
Range 0.1 μA to 10 A
Accuracy 27-II: 1.5 % + 2
28-II: 1.0 % + 2
Resistance
Range 0.1 Ω to 50 MΩ
Display counts
27-II 6000
28-II 6000/19,999
Capacitance

1 nF to 9999 μF
Frequency

0.5 Hz to 199.99 kHz
Temperature

27-II: N/A
28-II: -200 °C to +1090 °C
Low pass filter (Measurement on VSD’s)

27-II: N/A
28-II: Yes
Compliance

CAT IV 600 V , CAT III 1000V
IP rating
27-II: IP 67
28-II: IP 67
Power

Three AA batteries
Battery life

800 hours

General specifications
Display
Bar graph/backlight Yes/Yes
Data storage
Peak transient capture 250 μS (28 II)
Min/Max/Avg Yes
Reading hold Yes
Other features
Relative readings (zero) Yes
Battery type Three AA batteries
Warranty and protection
Safety rating CAT IV 600 V/CAT III 1000 V
External protection Rubber holster
Drop test 10 feet drop test
Dustproof/waterproof Yes, IP 67 rated
Warranty Limited lifetime
Size (HxWxL) with holster 6.35 cm x 10.0 cm x 19.81 cm (2.5 in x 3.93 in x 7.8 in)
Weight with holster 698.5 g (1.54 lb)