Fluke 345 Power Quality Clamp Meters

Fluke 345 Power Quality Clamp Meter


Fluke 345 Power Quality Clamp Meter


DESCRIPTION

This clamp on meter is a combination power analyzer, power quality logger, and clamp meter, and is ideal for monitoring electronic loads.

With the bright color power meter display to analyze the harmonic spectrum, a low-pass filter to remove high frequency noise, and a high EMC immunity design, the Fluke 345 power analyzer is ideal for troubleshooting power quality on switching loads. Additionally, the Hall Effect clamp meter design makes measurement of dc current possible without the need to break the circuit with the power meter. The internal memory of the power analyzer enables long-term power quality logging for analysis of trends or intermittent problems.

APPLICATIONS

  • Setup and troubleshoot variable frequency drives and UPS systems - Verify correct operation by measuring key power quality parameters
  • Harmonics measurements - Uncover harmonic issues that can damage or disrupt critical equipment
  • Inrush capture - Check start-up current where spurious resets or nuisance circuit breaker tripping occurs
  • Load studies - Verify electrical system capacity before adding loads

FEATURES
  • AC/DC current: Clamp-on measurement of ac current up to 1400 A rms and dc current up to 2000 A without breaking the circuit
  • Highest safety rating: 600 V CAT IV power analyzer is rated for use at the service entrance
  • Accurate in noisy environments: Clamp meter performs even with distorted waveforms present on electronic loads with low-pass filter
  • Data logging: Identify intermittent faults by logging any power quality parameter for minutes, or over a month, including harmonics
  • Verify batteries: Direct measurement of dc ripple (%) for battery and dc systems
  • Troubleshoot harmonics: Analyze and log harmonics digitally or graphically
  • Inrush current: Capture and analyze nuisance tripping, from 3 seconds to 300 seconds
  • Easy to use: Easily confirm power meter setup with large backlit color display of waveforms and trends
  • 3-Phase power: Built in capability for balanced loads
  • View graphs and generate reports: Use power analyzer with included Power Log software

GENERAL SPESIFICATIONS

Reference conditions
All accuracies stated at 23˚C ± 1˚C (73.4 °F ± 1.8 °F)
Operating temperature
0 °C to 50 °C (32 °F to 122 °F)
Temperature coefficient of current
≤ ± 0.15 % of rdg per °C
Temperature coefficient of voltage
≤ ± 0.15 % of rdg per °C
Maximum relative humidity
80 % for temperatures up to 31 °C (87 °F) decreasing linearly to 50 % relative humidity at 40 °C (104 °F)
Maximum operating altitude
2000 m
Measuring range
0 to 2000 A dc or 1400 ac rms
Autorange facility
40 A / 400 A / 2000 A
Resolution
10 mA in 40 A range
100 mA in 400 A range
1 A in 2000 A range
Accuracy: DC and dc rms
I > 10 A:± 1.5 % rdg ± 5 digits
I < 10 A:± 0.2 A
Accuracy: AVG
I > 10 A:± 3 % rdg ± 5 digits
I < 10 A:± 0.5 A
Accuracy: Pk
I > 10 A:± 5 % rdg ± 5 digits
I < 10 A:± 0.5 A
Accuracy: AHr
I > 10 A:± 2 % rdg ± 5 digits
I < 10 A:± 0.5 AHr
Accuracy: CF (Crest Factor)
1.1 ≤ CF < 3:± 3 % rdg ± 5 digits
3 ≤ CF < 5:± 5 % rdg ± 5 digits
Resolution:0.01
Accuracy: RPL (Ripple)
2 % ≤ RPL < 100 %:± 3 % rdg ± 5 digits
100 % ≤ RPL < 600 %:± 5 % rdg ± 5 digits
Resolution:0.1 %
Idc > 5 A, Iac > 2 A

 Distributed By : www.ralali,com Agen FLUKE Indonesia 


Fluke 355 / 353 True-rms 2000 A Clamp Meters

Fluke 355 dan 353 True-rms 2000 A Clamp Meters

Fluke 355 dan 353 True-rms 2000 A Clamp Meters



DESCRIPTION

Versatile and rugged tools for applications with high currentsConfidently take reliable readings with the True-rms, Fluke 355 and 353 digital clamp meters; the tools of choice for high current clamp-on amp meter measurement up to 2000 A. The extra-wide jaw easily clamps around large conductors, typically found in high-current applications. The extra rugged design and CAT IV 600 V, CAT III 1000 V ratings add an extra element of user protection when taking high-powered measurements.

Accurate peak measurements can be taken using the in-rush current mode, ideal for motors and inductive loads. The 355 also measures voltage and resistance, making this an ideal clamp meter for utilities, electrical contractors and industrial service technicians.

FEATURES
  • Reliably handle a wide range of high-current applications with 2000 A ac + dc true-rms, 1400 A ac, and 2000 A dc
  • The large 58 mm (2.3 in) jaw capacity is suitable for large or multiple conductors
  • CAT IV 600 V, CAT III 1000 V rating for added user protection
  • In-rush current measurement captures ‘power-on’ surge current with accuracy and repeatability
  • High voltage measurement of 1000 V ac + dc true-rms, 600 V ac, and 1000 V dc allows the user to perform multiple tests with only one tool (355 only)
  • Resistance to 400K ohms coupled with a continuity beeper provide the convenience of a multimeter in a clamp meter. (355 only)
  • Accurately measure frequency up to 1 kHz for optimum troubleshooting
  • Quickly analyze readings using the MIN, MAX, and AVG functions
  • A large backlit display allows for easy visibility in low-lit areas
  • Use the display hold feature to capture readings even when the display cannot be viewed
  • Use the low-pass filter to smooth out noisy loads and stabilize readings

GENERAL SPESIFICATIONS
Batteries
Six 1.5 V AA NEDA 15 A or IEC LR6
Battery life (with typical usage, backlight off)
100 hours
Test leads
Rated to 1000 V
Weight
.814 kg (1.8 lb)
Jaw size
58 mm (2.28 in)
Dimensions (LxWxD)
300 mm x 98 mm x 52 mm (12 in x 3.75 in x 2 in)
Safety rating
IEC 61010-2-032, 600 V CAT IV, 1000 V CAT III

Distributed By : www.ralali,com , Distributor agen FLUKE Indonesia

Twitter Delicious Facebook Digg Stumbleupon Favorites More