| Accuracy Specifications | 
   | AC Volts (40 Hz to 500Hz)1
 | Range | Resolution | Accuracy | 
   | 6.000 V 60.00 V
 600.0 V
 | 0.001 V 0.01 V
 0.1 V
 | 1.0 % + 3 | 
   | DC Volts | 6.000 V 60.00 V
 600.0 V
 | 0.001 V 0.01 V
 0.1 V
 | 0.5 % + 3 | 
   | AC Millivolts | 600.0 mV | 0.1 mV | 3.0 % + 3 | 
   | Diode Test2 | 2.000 V | 0.001 V | 10 % | 
   | Resistance (Ohms)
 | 400.0 Ω 4.000 kΩ
 40.00 kΩ
 400.0 kΩ
 4.000 MΩ
 40.00 MΩ
 | 0.1 Ω 0.001 kΩ
 0.01 kΩ
 0.1 kΩ
 0.001 MΩ
 0.01 MΩ
 | 0.5 % + 3 0.5 % + 2
 0.5 % + 2
 0.5 % + 2
 0.5 % + 2
 1.5% + 3
 | 
   | Capacitance3 | 50.00 nF 500.0 nF
 5.000 μF
 50.00 μF
 500.0 μF
 1000 μF
 | 0.01 nF 0.1 nF
 0.001 μF
 0.01 μF
 0.1 μF
 1 μF
 | 2 % + 5 2 % + 5
 5 % + 5
 5 % + 5
 5 % + 5
 5 % + 5
 | 
   | Frequency4 Hz
 (10 Hz – 100 kHz)
 | 50.00 Hz 500.0 Hz
 5.000 kHz
 50.00 kHz
 100.0 kHz
 | 0.01 Hz 0.1 Hz
 0.001 kHz
 0.01 kHz
 0.1 kHz
 | 0.1 % + 3 | 
   | Duty Cycle4 | 1 % to 99 % | 0.1 % | 1 % typical 5 | 
   | AC Current (40 Hz to 200 Hz)
 | 4.000 A 10.00 A
 | 0.001 A 0.01 A
 | 1.5 % + 3 | 
   | DC Current | 4.000 A 10.00 A
 | 0.001 A 0.01 A
 | 1.5 % + 3 | 
   | 
All AC, Hz, and duty cycle are specified from 1 % to 100 % of range. Inputs below 1 % of range are not specified.Typically, open circuit test voltage is 2.0 V and short circuit current is <0.6 mA.Specifications do not include 
errors due to test lead capacitance and capacitance floor (may be up to 
1.5 nF in the 50 nF range).All AC, Hz, and duty cycle are specified from 1 % to 100 % of range. Inputs below 1 % of range are not specified.Typical means when the frequency is at 50 Hz or 60 Hz and the duty cycle is between 10 % and 90 % | 
   | Function | Overload Protection | Input Impedance (Nominal) | Common Mode Rejection Ratio | Normal Mode Rejection Ratio | 
   | AC Volts | 600 V 1 | >10 MΩ <100 pF 2 | >60 dB at dc, 50 Hz or 60 Hz
 | − | 
   | AC Millivolts | 600 mV | >1M, <100 pF | >80 dB at 50 Hz or 60 Hz | − | 
   | DC Volts | 600 V 1 | >10 MΩ <100 pF | >100 dB at dc, 50 Hz or 60 Hz
 | >60 dB at 50 Hz or 60 Hz | 
   | 
6 x 105 V Hz MaxFor mV (AC), input impedance is approximately 1 MΩ. | 
   | General Specifications | 
   | Maximum Voltage Between any Terminal and Earth Ground | 600 V | 
   | Display (LCD) | 6000 counts, updates 3/sec | 
   | Battery Type | 2 AAA, NEDA 24A, IEC LR03 | 
   | Battery Life | 200 hours minimum | 
   | Temperature | 
   | Operating | 0 °C to 40 °C | 
   | Storage | -30 °C to 60 °C | 
   | Relative Humidity | 
   | Operating Humidity | Non-condensing when <10°C ≤90 % at 10 °C to 30 °C; ≤75 % at 30 °C to 40 °C
 | 
   | Operating Humidity, 40 MΩ Range | ≤80 % at 10 °C to 30 °C; ≤70 % at 30 °C to 40 °C | 
   | Altitude | 
   | Operating | 2000 m | 
   | Storage | 12,000 m | 
   | Temperature Coefficient | 0.1 X (specified accuracy) /°C (<18 °C or >28 °C) | 
   | Fuse Protection for Current Inputs | 11A, 1000V Fast Fuse, Fluke specified part only 
 
 | 
   | Size (HxWxL) | 142 mm x 69 mm x 28mm | 
   | Weight | 200 g | 
   | IP Rating | IEC 60529: IP 40 | 
   | Safety | IEC 61010-1: 600 V CAT III, Pollution Degree 2 | 
   | Electromagnetic Environment | IEC 61326-1: Portable | 
   | Electromagnetic Compatibility | Applies to use the Korea only.  Class A Equipment (Industrial Broadcasting and Communication Equipment)1 |