Selasa, 11 Desember 2012

Digital Multimeter Fluke 80 Series V

Digital Multimeter  Fluke 80 Series V

Lihat lainnya di www.ralali.com

Digital Multimeter  Fluke 80 Series V


Description

Accuracy and diagnostic functions for maximum industrial productivityThe new Fluke 87V has improved measurement functions, trouble-shooting features, resolution and accuracy to solve more problems on motor drives, in plant automation, power distribution and electro-mechanical equipment.

The New Fluke 80 Series consists on the following models:
  • Fluke 83 V Industrial DMM
  • Fluke 87 V True RMS Industrial DMM
  • Fluke 87 V/E2 Industrial Electricians Combo Kit
  • Data logging DMM available
The 80 Series V operates very similar to the classic 80 series, but with more problem solving power, safety, convenience and impact protection.

The new 80 series V are independently tested to comply with the 2nd edition of ANSI/ISA S82.01 and EN61010-1 CAT IV 600V/CAT III 1000V. They can withstand impulses in excess of 8,000 V and reduce risks related to surges and spikes.

FEATURES
  • Unique function for accurate voltage and frequency measurements on adjustable speed motor drives and other electrically noisy equipment (87V)
  • Built-in thermometer conveniently allows you to take temperature readings without having to carry a separate instrument (87V)
  • Optional magnetic hanger for easy set-up and viewing while freeing your hands for other tasks
  • Large digit display with bright, two-level backlight makes the 80- Series V significantly easier to read than older models

Specifications
Voltage DC
Maximum Voltage: 1000V
Accuracy: Fluke 83 V: ±(0.1%+1)
Fluke 87 V: ±(0.05%+1)
Maximum Resolution: Fluke 83 V: 100 µV
Fluke 87 V: 10 µV
Voltage AC
Maximum Voltage: 1000V
Accuracy: Fluke 83 V: ±(0.5%+2)
Fluke 87 V: ±(0.7%+2) True RMS
AC Bandwidth Fluke 83 V: 5kHz
Fluke 87 V: 20kHz*
*with low pass filter; 3db @ 1kHz
Maximum Resolution: 0.1 mV
Current DC
Maximum Amps: 10A (20 A for 30 seconds maximum)
Amps Accuracy: Fluke 83 V: ±(0.4%+2)
Fluke 87 V: ±(0.2%+2)
Maximum Resolution: Fluke 83 V: 0.01 mA
Fluke 87 V: 0.01 µA
Current AC
Maximum Amps: 10A (20 A for 30 seconds maximum)
Amps Accuracy: Fluke 83 V: ±(1.2%+2)
Fluke 87 V: ±(1.0%+2) True RMS
Maximum Resolution: 0.1 µA
Resistance
Maximum Resistance: 50 MΩ
Accuracy: Fluke 83 V: ±(0.4%+1)
Fluke 87 V: ±(0.2%+1)
Maximum Resolution: 0.1Ω
Capacitance
Maximum Capacitance 9,999 µF
Accuracy ±(1%+2)
Maximum Resolution 0.01 nF
Frequency
Maximum Frequency 200 kHz
Accuracy ±(0.005%+1)
Maximum Resolution 0.01 Hz
Duty Cycle
Maximum Duty Cycle 99.9%
Accuracy ±(0.2% per khz +0.1%)
Maximum Resolution 0.1%
Temperature Measurement
Fluke 87 V, 87 V/E: -200.0°C - 1090°C

-328.0°F - 1994.0°F

excluding probe
80 BK Temperature Probe

-40.0°C - 260°C

-40.0°F - 500°F, 2.2°C or 2% whichever is greater
Conductance
Maximum Conductance 60.00 nS
Accuracy ±(1.0%+10)
Maximum Resolution 0.01 nS
Diode
Range: 3 V
Resolution: 1 mV
Accuracy: ± (2 % + 1)
Duty Cycle Range
Accuracy: Within ± (0.2% per kHz + 0.1 %)


Distributed By : www.ralali.com ,Distributor FLUKE Indonesia

0 komentar:

Posting Komentar

Catatan: Hanya anggota dari blog ini yang dapat mengirim komentar.

Twitter Delicious Facebook Digg Stumbleupon Favorites More