| Accuracy Specifications |
| DC millivolts |
| Range: | 600.0 mV |
| Resolution: | 0.1 mV |
| Accuracy: | ± ([% of reading] + [counts]): 0.5% + 2 |
|
| DC volts |
| Range/Resolution: | 6.000 V / 0.001 V |
| Range/Resolution: | 60.00 V / 0.01 V |
| Range/Resolution: | 600.00 V / 0.1 V |
| Accuracy: | ± ([% of reading] + [counts]): 0.5% + 2 |
|
| Auto volts |
| Range: | 600.0 V |
| Resolution: | 0.1 V |
| Accuracy: | 2.0 % + 3 (dc, 45 Hz to 500 Hz) 4.0 % + 3 (500 Hz to 1 kHz) |
|
| AC millivolts1 true-rms |
| Range: | 600.0 mV |
| Resolution: | 0.1 mV |
| Accuracy: | 1.0 % + 3 (dc, 45 Hz to 500 Hz) 2.0 % + 3 (500 Hz to 1 kHz) |
|
| AC volts1 true-rms |
| Range/Resolution: | 6.000 V / 0.001 V |
| Range/Resolution: | 60.00 V / 0.01 V |
| Range/Resolution: | 600.0 V / 0.1 V |
| Accuracy: | 1.0 % + 3 (dc, 45 Hz to 500 Hz) 2.0 % + 3 (500 Hz to 1 kHz) |
|
| Continuity |
| Range: | 600 Ω |
| Resolution: | 1 Ω |
| Accuracy: | Beeper on < 20 Ω, off > 250 Ω; detects opens or shorts of 500 μs or longer. |
|
| Ohms |
| Range/Resolution: | 600.0 Ω / 0.1 Ω |
| Range/Resolution: | 6.000 kΩ / 0.001 kΩ |
| Range/Resolution: | 60.00 kΩ / 0.01 kΩ |
| Range/Resolution: | 600.0 kΩ / 0.1 kΩ |
| Range/Resolution: | 6.000 MΩ / 0.001 MΩ |
| Accuracy: | 0.9 % + 1 |
| Range/Resolution: | 40.00 MΩ / 0.01 MΩ |
| Accuracy: | 5 % + 2 |
|
| Diode Test |
| Range/Resolution: | 2.000 V / 0.001 V |
| Accuracy: | 0.9% + 2 |
|
| Capacitance |
| Range/Resolution: | 1000 nF / 1 nF |
| Range/Resolution: | 10.00 μF / 0.01 μF |
| Range/Resolution: | 100.0 μF / 0.1 μF |
| Range/Resolution: | 9999 μF / 1 μF |
| Range/Resolution: | 100 μF to 1000 μF |
| Accuracy: | 1.9% + 2 |
| Range/Resolution: | > 1000 μF |
| Accuracy: | 5% + 20% |
|
| LoZ capacitance |
| Range: | 1 nF to 500 μF |
| Accuracy: | 10% + 2 typical |
|
| AC amps true-rms (45 Hz to 500 Hz) |
| Range/Resolution: | 6.000 A / 0.001 A |
| Range/Resolution: | 10.00 A / 0.01 A |
| Accuracy: | 1.5% + 3 |
| 20 A continuous overload for 30 seconds max |
|
| DC amps |
| Range/Resolution: | 6.000 A / 0.001 A |
| Range/Resolution: | 10.00 A / 0.01 A |
| Accuracy: | 1.0% + 3 |
| 20 A continuous overload for 30 seconds max |
|
| Hz (V or A input)2 |
| Range/Resolution: | 99.99 Hz / 0.01 Hz |
| Range/Resolution: | 999.99 Hz / 0.1 Hz |
| Range/Resolution: | 9.999 Hz / 0.001 Hz |
| Range/Resolution: | 50.00 Hz / 0.01 Hz |
| Accuracy: | 0.1% + 2 |
|
0 komentar: