The first four- and two-channel scopes built for CAT IV industrial environments
  • Extend your arsenal of troubleshooting capabilities by visually inspecting signals amplitude, time, shape and disturbance or distortion characteristics.
  • The Fluke 190 series combines the power of a high performance oscilloscopemultimeter and paperless recorder in an easy to use test tool you will come to rely on in the field.
Fluke 190 Series II -- 20 years of ScopeMeter Test Tool Innovation.

As the first two and four-channel portable scopes safety rated CAT III 1000V / CAT IV 600V,
the Fluke ScopeMeter 190 Series II combines an unprecedented level of performance, ruggedness, and portability.
You can choose from 60MHz, 100MHz, 200MHz or 500MHz bandwidth models,
with real-time sampling rates up to 5 GS/s and 200 ps resolution to capture noise and other disturbances.
Both models feature deep memory—up to 10,000 samples per channel— so you can examine very small parts of the waveform in detail.
And both are IP-51 rated to withstand dust, drips, humidity, and wide temperature variations.
Fluke ScopeMeter test tools are hand-held battery operated, designed to meet the demands of field service professionals.

Fix More with the Two and Four-Channel CAT IV Rated Fluke ScopeMeter 190 Series II

The Fluke ScopeMeter 190 Series II combine the highest safety ratings and rugged portability with the high performance of a bench oscilloscope. Designed for plant maintenance engineers and technicians, these tough ScopeMeter test tools go into harsh, dirty, and hazardous industrial conditions to test everything from microelectronics to power electronics applications.
The 190 Series II is the one test tool you will reach for to tackle just about any troubleshooting task. They include amultimeter, TrendPlot  and ScopeRecord  roll paperless recorder modes and hands free operation with Connect-and-View™ triggering, and much more:
  • Two or four electrically isolated inputs
  • CAT III 1000V / CAT IV 600V safety rated
  • Choose from 60 MHz, 100MHz, 200MHz or 500MHz bandwidth models
  • Fast sampling rate, up to 5GS/s with up to 200 ps resolution (Depending on model and channels used)
  • Deep memory: 10,000 samples per channel waveform capture so you can zoom in on the details
  • Dedicated 5000 Count digital multimeter in 2 Channel models
  • Quad meter measurements via scope BNC inputs in 4 channel models
  • Connect-and-View continuous auto-trigger, single shot, pulse width, and video triggering
  • ScopeRecord roll mode, capture waveform sample data for up to 48 hours
  • TrendPlot, trend measurement readings for up to 22 days
  • Advanced automatic measurements, power (Vpwm, VA, W, PF) and time (mAs, V/s, w/s)
  • IP-51 rated for dust and drip proof to withstand harsh environments
  • Isolated USB ports for memory devices and PC connectivity
  • Li-Ion battery for extended operating timespan
    • 190-X04, 4 Channel models up to 7 hour (BP291 included standard)
    • 190-XX2, 2 Channel models up to 4 hours (BP290 included standard) or up to 8 hour with optional BP291
    • Charge spare battery using optional external battery charger EBC290
  • Easy-access battery door to make it easy to swap batteries
  • A handy slot to tether and lock down the oscilloscope while unattended using a standard Kensington® lock

Specifications

Bandwidth
Fluke 190-502: 500 MHz
Fluke 190-204: 200 MHz
Fluke 190-202: 200 MHz
Fluke 190-104: 100 MHz
Fluke 190-102: 100 MHz
Fluke 190-062: 60 MHz
Number of Channels
Fluke 190-502: 500 MHz: 2 channels
Fluke 190-204: 200 MHz: 4 channels
Fluke 190-202: 200 MHz: 2 channels
Fluke 190-104: 100 MHz: 4 channels
Fluke 190-102: 100 MHz: 2 channels
Fluke 190-062: 60 MHz: 2 channels
Real-time sample rate
Fluke 190-502: 5 GS
Fluke 190-204: 2.5 GS/s
Fluke 190-202: 2.5 GS/s
Fluke 190-104: 1.25 GS/s
Fluke 190-102: 1.25 GS/s
Fluke 190-062: 625 MS/s
Inputs
4 scope or 2 scope plus DMM input
Independently floating isolated inputs
Up to 1000 V CAT III/600 V CAT IV between inputs, references and ground
Timebase range
2 ns - 2 min/div (190-20X, 200 MHz models)
5 ns - 2 min/div (190-10X, 100 MHz models)
10 ns - 2 min/div (190-062, 60 MHz model)
Input sensitivity
2 mV-100 V/div
Trigger types
Connect-and-View™, Free Run, Single Shot, Edge, Delay, Dual Slope, Video, Video Line, Selectable pulse width, N-Cycle
Trigger Source
Any scope input channel, or external via DMM input on 190-XX2, 2 channel models
Glitch capture
8 ns
Scope measurements
Cursor: 7
Automatic: 30
Maximum record length
ScopeRecord mode: 30,000 pts
Scope mode: 10,000 pts per input
Persistence
Digital persistence giving analog oscilloscope-like waveform decay
Waveform Compare
Waveform reference with automatic Pass/Fail testing

DMM Specification (2-channel models)

Meter inputs (also used as External Trigger Input for the Oscilloscope Mode)
4 mm banana inputs, fully isolated from scope inputs and from scope ground
Maximum Resolution:
5000 counts
Measurements:
Vdc, Vac rms, Vac+dc rms, Resistance, Continuity, Diode Test, Current (through clamp or shunt), Temperature ºC or ºF (using optional converter)
Memory
190-XX2, 2 Channel
Screen + Setup: 30
Recording: 10
Display
153 mm full color LCD with fast update rate

Environmental Specifications

Operating Temperature
0ºC to 40ºC Including Batteries
0ºC to 50ºC Excluding Batteries
Storage Temperature
-20°C to +60°C
Operating Altitude
Up to 2,000 m (6666 ft) for CAT IV 600 V, CAT III 1000 V
Up to 3,000 m (10,000 ft) for CAT III 600 V, CAT II 1000 V

Safety Specifications

Electrical Safety
1,000V CAT III/600V CAT IV (EN61010-1)

Mechanical & General Specifications

Size
270 x 190 x 70 mm
Weight
2.2 kg
Warranty
3-years on main instrument, 1-year on accessories
Li-Ion Battery
190-XX2, 2 Channel models 190 BP291 4800 mAh battery up to 7 Hours included standard

Included Accessories

Two channel models
VPS410 Voltage Probe Sets (one red, one blue)
TL175 TwistGuard™ safety designed Test Lead Set (red and black)
BC190 Battery Charger/mains Adapter
BP290 2400 mAh Li-ion Battery
Handstrap (affixed to instrument)
Hangstrap
Multi-Language User Manuals on CD-Rom
FlukeView ScopeMeter demo package (restricted functionality)
USB Interface Cable
Four channel models
VPS410 Voltage Probe Sets (one red, one blue, one grey, one green)
BC190 Battery Charger/mains Adapter
BP291 4800 mAh high capacity Li-ion Battery
Handstrap (affixed to instrument)
Hangstrap
Multi-Language User Manuals on CD-Rom
FlukeView ScopeMeter demo package (restricted functionality)
USB Interface Cable
Warranty
Three years on main instrument, one year on accessories




Tags: alat ukur listrikmultimeterfluke clamp metermeasuring instrumenttest equipmentdigital multi meterdigital meter,clamp meterfluke priceharga flukejual flukefluke meterdistributor flukefluke digital multimeterfluke indonesiafluke,fluke multimetermulti meter flukedistributor FlukescopemeterFluke 190 Series II,